Differences between revisions 3 and 4
Revision 3 as of 2021-07-29 09:00:52
Size: 2289
Editor: DonPark
Comment: 2021-07-24 visit notes
Revision 4 as of 2021-07-29 09:01:57
Size: 2338
Editor: DonPark
Comment:
Deletions are marked like this. Additions are marked like this.
Line 30: Line 30:
 *  * pics https://photos.app.goo.gl/vfmBqY8vrCGG5DjL8

Node name: NodeC3PO
Live Date: May 3, 2020
Sponsor: PersonalTelco and a friendly neighboring business
Contact:

SE Water Avenue
Portland, OR

Configuration

  • Host: jet

    • Hardware: Ubiquiti ER-X and two Meraki MR24s
    • Software: OpenWRT

    • Internet IPv4: DHCP
    • PTPnet IPv4: 10.11.70.1/23

Installers / Organizers

Maintenance and System Log

  • 2020-05-03: Gear installed
  • 2021-02-20: Maintenance involving replacement of power supplies (due to sabotage) and provision of an enclosure to enhance security of the devices
  • 2021-06-12: Reports of problems with ethernet run across the street (possible damage) and possible water intrusion into AP2 (at the south village), requesting more information.
  • 2021-07-01: Outage intensified as the heatwave came on and it was not functioning over the weekend. Got down there the evening of 6/30, but missed Andrew, so came back today (he has the key to the enclosure), found the ER-X not working correctly, took it home, discovered a bad-block error in the NAND flash in the /rom section, rendering part of the squashfs unreadable, explaining the failure to connect its network despite powering the NanoBeam, recovered by TFTP booting a initramfs image, then reflashing (this seems to map out the bad block via the ubi block layer), and it seemed to function properly after that. I cleaned up the case, relabelled the ports for more clarity and also printed labels for the ethernet cables to ensure they are plugged in correctly. --RussellSenior

  • 2021-07-24: North camp vacated along with the antenna. Russell and Jason recovered the antenna, installed it in South Camp. Installed enclosure in reception room. Ran ethernet from outside to inside reception room. Setup one AP on top of the enclosure. Ran ethernet along outside fence to setup a second AP at South Camp mid-point. --DonPark

Notes


[CategoryNode][CategoryPersonalTelco]

NodeC3PO (last edited 2021-07-29 11:15:13 by RussellSenior)