Mississippi Network Diagram and Configuration
A nucab named "mississippi" serves DHCP and does NAT for our DSL line. All of the metrix boxes run ["STP"]. The whole network is bridged, and in the 10.11.104.0/22 network.
We have MississippiMonitoring with Cacti: http://buick.personaltelco.net/cacti/graph_view.php
Include(MississippiNetworkNews, "NEWS", 2, from="^.*$")
TODO
- Check polarization on metrix-ed's 11a antenna (should be same as metrix-naya-sw).
- Try repointing metrix-ed's 11a antenna at metrix-commons. If successful:
- Repoint metrix-naya-nw's 11a antenna at metrix-commons; and
- Replace metrix-naya-sw with the Commons cisco.
- The Sector antennas on Naya might benefit from being repointed...
- Install link to second DSL line (in bookstore) and setup round-robin load balancing
- Need to install a "repeater" at Amnesia brewing inside and behind the corrogated steel.
- What's the deal with Broadcom-based client devices connected to Atheros based APs? Why doesn't it work? Under what circumstances (if any) will it? [Troy said he no longer has the problem with the current madwifi drivers, thinks it was a problem with the old wds-branch code].
Access points
Location |
Part of roof |
Hardware |
Interface/IP address |
Int/Channel |
Antenna |
NAYA |
SW corner |
Metrix |
br0(eth0,ath0,ath1)/10.11.104.2 |
wifi0/165(wds to commons) |
17 dBi to Commons |
wifi1/1 |
9 dbi 120deg pointing S |
||||
NW corner |
Metrix |
br0(eth0,ath0,ath1)/10.11.104.3 |
wifi0/165(wds to ed) |
17 dBi to Ed's |
|
wifi1/11 |
9 dbi 120deg pointing NW |
||||
SE corner |
Cisco |
BVI1(Dot11Radio0,FastEth0)/10.11.104.4 |
Dot11Radio0/11 |
9 dbi 120deg pointing E |
|
Commons |
SE corner |
Metrix |
br0(eth0,ath0,ath1)/10.11.104.5 |
wifi0/165(wds to naya-sw,west) |
8 dBi 802.11a omni |
wifi1/1 |
7 dBi omni (w/down-tilt) |
||||
Cisco |
BVI1(Dot11Radio0,FastEth0)/10.11.104.6 |
Dot11Radio0/11 |
9 dBi 120deg pointing SE |
||
Dog shop |
Edimax |
??/10.11.104.15 |
??/?? |
integrated omni |
|
Cecily's |
Chimney |
Metrix |
br0(eth0,ath0,ath1)/10.11.104.8 |
wifi0/165(wds to commons) |
17 dBi to Commons |
wifi1/1 |
9 dBi omni |
||||
Ed's |
Chimney |
Metrix |
br0(eth0,ath0,ath1)/10.11.104.9 |
wifi1/165(wds to naya-nw) |
17 dBi to NAYA NW |
wifi0/1 |
9 dBi omni |
See ChannelFrequencyChart for reasoning about channels, and channel choices.
MAC addresses
mississippi |
Interface |
MAC |
64.105.215.242 |
eth0 |
00:00:F8:06:C0:37 |
10.11.104.1 |
eth1 |
00:10:5A:04:1E:09 |
metrix-naya-sw |
Interface |
MAC |
10.11.104.2 |
wifi0 |
00:02:6F:21:EC:AA |
wifi1 |
00:02:6F:21:EC:A5 |
|
eth0(br0) |
00:00:24:C3:A9:C0 |
|
metrix-naya-nw |
Interface |
MAC |
10.11.104.3 |
wifi0 |
00:02:6F:21:EC:A8 |
wifi1 |
00:02:6F:21:EC:A6 |
|
eth0(br0) |
00:00:24:C3:A9:B4 |
|
metrix-commons |
Interface |
MAC |
10.11.104.5 |
wifi0 |
00:02:6F:21:EC:A9 |
wifi1 |
00:02:6F:21:E9:49 |
|
eth0(br0) |
00:00:24:C3:A9:A0 |
|
cisco-commons |
Interface |
MAC |
10.11.104.6 |
bridge |
00:0F:34:DF:9A:DD |
metrix-west |
Interface |
MAC |
10.11.104.8 |
wifi0 |
00:02:6F:21:EF:ED |
wifi1 |
00:02:6F:21:EF:F2 |
|
eth0(br0) |
00:00:24:c3:a9:ac |
|
metrix-ed |
Interface |
MAC |
10.11.104.9 |
wifi0 |
00:02:6F:21:EF:F0 |
wifi1 |
00:02:6F:21:EF:F1 |
|
eth0(br0) |
00:00:24:C3:E4:1C |
|
metrix-troy (not deployed) |
Interface |
MAC |
10.11.104.x |
eth0 |
00:00:24:C3:E4:30 |
metrix-russell (not deployed) |
Interface |
MAC |
10.11.104.y |
ath0 |
00:02:6F:21:EC:A2 |
ath1 |
00:02:6F:21:EC:A1 |
|
eth0(br0) |
00:00:24:C3:A9:B8 |
|
metrix-dje (not deployed) |
Interface |
MAC |
10.11.104.z |
ath0 |
00:02:6f:20:f7:2b |
ath1 |
00:02:6f:21:e8:2b |
|
eth0(br0) |
00:00:24:c2:39:d0 |
|
edimax-commons |
Interface |
MAC |
10.11.104.15 |
bridge |
00:0E:2E:3C:4B:7D |
edimax-freshpot |
Interface |
MAC |
10.11.104.16 |
bridge |
00:0e:2e:3c:4b:88 |
RussellSenior currently has both metrix-russell and metrix-dje setup in a test rig. Metrix-dje uses a Soekris 4526 board with 486 processor, different than the standard Metrix Mark II we are using on the project, which use a Soekris 4826 board with a Geode (pentium-like) processor. TroyJaqua has metrix-troy.
See MississippiMetrixConfiguration for a method of preparing and updating the software on the metrixes.